    A high-throughput whole-body PET scanner using flat panel PS-PMTs

  • Author

    Watanabe, M. ; Shimizu, K. ; Omura, T. ; Sato, N. ; Takahashi, M. ; Kosugi, T. ; Ote, K. ; Katabe, A. ; Yamada, R. ; Yamashita, T. ; Tanaka, E.

  • Author_Institution
    Hamamatsu Photonics K.K, Hamakita-City, Japan
  • Volume
    51
  • Issue
    3
  • fYear
    2004
  • fDate
    6/1/2004 12:00:00 AM
  • Firstpage
    796
  • Lastpage
    800
  • Abstract
    A new positron emission tomography (PET) scanner for whole-body studies has been developed. The scanner has 720 block detectors, each of which consists of a flat panel position-sensitive photomultiplier and a 16×8 BGO crystal array. The detector system is composed of 12 layers of block detector rings stacked axially, and each ring consists of a circular array of 60 block detectors. Since each block detector ring contains eight crystal rings, the total number of detector rings is 96 and the axial field of view (FOV) is 685 mm, which is sufficient to measure a whole-body with two steps of scan. The detector ring diameter is 1 020 mm and the transaxial FOV is 600 mm in diameter. Coarse slice septa are placed between the block detector rings, which are effective to reduce scattered coincidence events while keeping a high detection sensitivity. Parallel 16 personal computers are used for the data acquisition and processing to deal with a large amount of event data. The acquired data in 3-D manner are converted to 2-D data set with Fourier rebinning algorithm and reconstructed with a fast iterative algorithm "DRAMA". The reconstructed images for the whole body are obtained within 5 min after the scan. By using the coarse septa, the scatter fraction measured with NEMA NU2-2001 standard was 31.4% whose value was significantly lower than that of 3-D PET without septa. The system sensitivity was 9.72 cps/kBq, and the peak counts of the noise equivalent count rate used with direct random-subtraction was 113.6 kcps at 10.5 kBq/ml.
  • Keywords
    data acquisition; image scanners; iterative methods; medical image processing; photomultipliers; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; 3-D PET; BGO crystal array; DRAMA; Fourier rebinning algorithm; NEMA NU2-2001 standard; axial field of view; block detectors; coarse slice septa; data acquisition; detection sensitivity; direct random-subtraction; fast iterative algorithm; flat panel position sensitive photomultiplier tubes; high-throughput whole-body PET scanner; noise equivalent count rate; personal computers; positron emission tomography scanner; transaxial field of view; Event detection; Image reconstruction; Iterative algorithms; Microcomputers; Photomultipliers; Position sensitive particle detectors; Positron emission tomography; Scattering; Sensor arrays; Whole-body PET; High-throughput; PET; position sensitive PMT; positron emission tomography; whole-body scan;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2004.829787
  • Filename
    1310600