DocumentCode :
1030816
Title :
BPA´s Extra High Voltage DC Tests: II - Outdoor Flashover
Author :
Hill, Harold L. ; Renner, P.E. ; Poland, Merle G. ; Scarborough, William E.
Author_Institution :
Bonneville Power Administration
Issue :
10
fYear :
1967
Firstpage :
1153
Lastpage :
1160
Abstract :
Laboratory tests were conducted to determine the dc flashover characteristics of rod gaps, line-to-tower air gaps, and suspension insulator assemblies. Direct current flashover for test voltages to 725 kV has been shown to be a linear function of specimen length for either polarity or for either wet or dry test conditions. Comparative data are presented for dc, ac, and switching surge test voltages.
Keywords :
Assembly; Flashover; Insulation testing; Insulator testing; Performance evaluation; Poles and towers; Power supplies; Surges; System testing; Voltage;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1967.291867
Filename :
4073176
Link To Document :
بازگشت