DocumentCode :
1030881
Title :
Stress-relieved magnetoelastic amorphous metal DC magnetometer
Author :
Mermelstein, M.D. ; Askins, C. ; Dandridge, A.
Author_Institution :
Naval Research Laboratory, Washington, USA
Volume :
23
Issue :
6
fYear :
1987
Firstpage :
280
Lastpage :
281
Abstract :
Reduction in the low-frequency stress-induced noise has improved the performance of a magnetoelastic amorphous metal fluxgate magnetometer by a factor of 20. This is accomplished by utilising a viscous fluid interface between the ribbon and its support structure. A minimum detectable field of 120pT/¿Hz is demonstrated.
Keywords :
magnetic field measurement; magnetometers; magnetostrictive devices; metallic glasses; DC magnetometer; low-frequency stress-induced noise; magnetic field measurement; magnetoelastic amorphous metal fluxgate magnetometer; minimum detectable field; viscous fluid interface;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19870204
Filename :
4257531