DocumentCode
1030935
Title
Mathematical Analysis of Double Line-to-Ground Short Circuit of an Alternator
Author
Hwang, Hu H.
Author_Institution
University of Hawaii
Issue
10
fYear
1967
Firstpage
1254
Lastpage
1257
Abstract
The performance equations of ac machines referring to the ¿and Ãaxes developed in a previous paper[1] are used to study the case of a double line-to-ground short circuit of a salient pole synchronous machine. Significant corrections are offered to the solutions proposed by other authors pertaining to the same case. Mathematical proof is established for such rectifications. As a result, new expressions for armature currents and field current are developed. In addition, decrement factors and a simple formula for X2 are derived.
Keywords
AC machines; Alternators; Circuits; Couplings; Equations; Machine windings; Mathematical analysis; Synchronous machines; Tensile stress; Voltage;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1967.291901
Filename
4073190