DocumentCode
1031271
Title
Localized hyperthermia by means of a paired-coil configuration: Calculation of current distributions in cubical model
Author
Ueno, S. ; Tashiro, T. ; Kamise, S. ; Harada, K.
Author_Institution
Kyushu University, Fukuoka, Japan
Volume
23
Issue
5
fYear
1987
fDate
9/1/1987 12:00:00 AM
Firstpage
2437
Lastpage
2439
Abstract
A method of localized hyperthermia of deep tissues by means of paired-coil arrays is proposed. The basic idea is to concentrate induced eddy currents in the vicinity of target tumors locally by paired coils positioned outside the body. Two coaxial pairs of coils are positioned on the surface of the body in parallel with each other in such a manner that the magnetic fields pass through the body in opposite directions around the target focus. To demonstrate the effectiveness of the method, spatial distributions of induced eddy currents are obtained in a cubical model by a finite element method.
Keywords
Eddy currents; Hyperthermia; Coils; Conductors; Current distribution; Eddy currents; Finite element methods; Heating; Hyperthermia; Magnetic fields; Magnetic flux; Neoplasms;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1987.1065671