DocumentCode :
1031392
Title :
Comments on ´Automated calibration of a fuzzy logic controller using a cell state space algorithm´ (with reply)
Author :
Smith, Stephen M. ; Comer, D.J.
Volume :
12
Issue :
3
fYear :
1992
fDate :
6/1/1992 12:00:00 AM
Firstpage :
120
Lastpage :
122
Abstract :
A shortcoming of the method presented in the above-titled article (ibid., vol.2, no.5, pp.18-28, Aug. 1991) when it is applied to a particular plant, namely, a DC motor with angular position feedback, is pointed out by the commenter. The authors elaborate on this shortcoming and correct some errors in the article.<>
Keywords :
DC motors; calibration; fuzzy logic; machine control; position control; DC motor; angular position feedback; automated calibration; cell state space algorithm; fuzzy logic controller;