DocumentCode :
1031542
Title :
Calculation of Spark Breakdown or Corona Starting Voltages in Nonuniform Fields.
Author :
Pedersen, A.
Author_Institution :
Department of Physics, Technical University of Denmark
Issue :
2
fYear :
1967
Firstpage :
200
Lastpage :
206
Abstract :
The processes leading to a spark breakdown or corona discharge are discussed very briefly. A quantitative breakdown criterion for use in high-voltage design is derived by which spark breakdown or corona starting voltages in nonuniform fields can be calculated. The criterion is applied to the sphere gap, and it is shown how it can give a very detailed and accurate description of known breakdown characteristics.
Keywords :
Breakdown voltage; Corona; Data engineering; Electric breakdown; Electrons; Gases; Geometry; Ionization; Physics; Sparks;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1967.291836
Filename :
4073260
Link To Document :
بازگشت