DocumentCode
1031773
Title
Sparkover in Mixtures of Air and Water Vapor
Author
Schmitz, Lawrence S. ; Penney, Gaylord W.
Author_Institution
STRATCOM, United States Army Signal Corps
Issue
3
fYear
1967
fDate
3/1/1967 12:00:00 AM
Firstpage
360
Lastpage
364
Abstract
Tests at 100°C, where large amounts of water vapor can be present in air, indicate that the effect of water vapor on sparking voltage depends on the type of sparking. In the relatively uniform field between sphere gaps the sparking voltage is found to increase by about 6 percent when the water vapor content of air is increased from 0 to 5 percent by volume. However this sparking voltage increases by only an additional 5 percent (to 11 percent) when the water vapor content is increased from 5 to 25 percent. However sparkover voltage of a one-inch gap in a non-uniform field and resulting from successive pulsed discharges shows a slighty smaller increase (5 percent) when the water vapor content is increased from 0 to 5 percent but doubles when the water vapor content is increased from 5 to 25 percent.
Keywords
Circuit testing; Electrodes; Electrostatic precipitators; Electrostatic processes; Gas industry; Humidity; Printing; Public healthcare; Temperature; Voltage;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1967.291963