DocumentCode :
1031923
Title :
Nonlinear Hydro Governing Model and Improved Calculation for Determining Temporary Droop
Author :
Undrill, J.M. ; Woodward, J.L.
Author_Institution :
General Electric Company
Issue :
4
fYear :
1967
fDate :
4/1/1967 12:00:00 AM
Firstpage :
443
Lastpage :
453
Abstract :
The linear governing equations of L. M. Hovey are extended to describe the major nonlinearities of a hydro electric generating set. The resultant nonlinear governing model can be used to simulate the small and large signal transient response of an isolated generating set under any loading condition, and comparisons of such simulations with test results are given. The analysis of the paper demonstrates that Hovey´s method of calculating temporary droop from a closed dashpot step response transient is inaccurate, and a corrected method is presented.
Keywords :
Computational modeling; Hydraulic turbines; Manufacturing; Nonlinear equations; Power generation; Power system modeling; Signal generators; Testing; Torque; Transient response;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1967.291853
Filename :
4073299
Link To Document :
بازگشت