DocumentCode
1032084
Title
Integrity of C2F6 in Gas Cooled Sealed Dry-Type Transformers
Author
Posner, G.G. ; Philosophos, John A. ; Manion, J.P.
Author_Institution
Electrical Transmission and Distribution Division of Allis-Chalmers
Issue
5
fYear
1967
fDate
5/1/1967 12:00:00 AM
Firstpage
568
Lastpage
570
Abstract
Gas filled dry-type transformers after three years of service were checked for evidence of corona. The C2F6 was found to be better than 96 percent pure and no evidence of corona was found.
Keywords
Availability; Condition monitoring; Coolants; Corona; Dielectric breakdown; Gas chromatography; Gases; Laboratories; Mass spectroscopy; Voltage transformers;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1967.291733
Filename
4073318
Link To Document