DocumentCode
1033841
Title
Bistable Operating Temperatures and the Current Rating of Sodium Conductors
Author
Hus, John
Author_Institution
Burndy Corporation,
Issue
2
fYear
1968
Firstpage
367
Lastpage
371
Abstract
Unlike conventional cables, the operating temperature of sodium cable lies close to its melting point. Although this does not affect the current rating at normal ambients, one cannot reap the full current rating benefits which normally accrue from a lowered ambient temperature. This paper describes how the ambient temperature affects the maximum operating temperature of sodium cable.
Keywords
Cables; Conductivity; Conductors; Connectors; Cooling; Equations; Heating; Steady-state; Temperature dependence; Testing;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1968.292031