Title :
Messapparatur zur genauen punktweisen bestimmung grossflächiger magnetfelder
Author_Institution :
AEG-Forschungsinstitut, Frankfurt, Germany.
fDate :
9/1/1966 12:00:00 AM
Abstract :
The principle underlying the method of automatic measurement of air gap flux densities is discussed. With this, a search coil is used and the voltage by time area is converted into a sequences of pulses in a voltage frequency transformer. An after-connected counter effects indication of the voltage by time area in decimal form. The measuring program can be punched in digital form on a tape. The accuracy obtainable as well as the various sources of errors are dealt with.
Keywords :
Magnetic flux measurement; Coils; Counting circuits; Density measurement; Frequency conversion; Gaussian processes; Magnetic devices; Magnetic field measurement; Magnetic flux; Pulse transformers; Stability;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1966.1065962