DocumentCode
1034319
Title
Messapparatur zur genauen punktweisen bestimmung grossflächiger magnetfelder
Author
Schadebrodt, G.
Author_Institution
AEG-Forschungsinstitut, Frankfurt, Germany.
Volume
2
Issue
3
fYear
1966
fDate
9/1/1966 12:00:00 AM
Firstpage
547
Lastpage
549
Abstract
The principle underlying the method of automatic measurement of air gap flux densities is discussed. With this, a search coil is used and the voltage by time area is converted into a sequences of pulses in a voltage frequency transformer. An after-connected counter effects indication of the voltage by time area in decimal form. The measuring program can be punched in digital form on a tape. The accuracy obtainable as well as the various sources of errors are dealt with.
Keywords
Magnetic flux measurement; Coils; Counting circuits; Density measurement; Frequency conversion; Gaussian processes; Magnetic devices; Magnetic field measurement; Magnetic flux; Pulse transformers; Stability;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1966.1065962
Filename
1065962
Link To Document