DocumentCode
1035304
Title
Nonlinear reactors as protective elements for thyristor circuits
Author
Paice, Derek A. ; Wood, Peter
Author_Institution
Westinghouse Electric Corporation, Pittsburgh, Pa
Volume
3
Issue
3
fYear
1967
fDate
9/1/1967 12:00:00 AM
Firstpage
228
Lastpage
232
Abstract
Control of rate of change of current and voltage in thyristor power circuits is provided in diverse ways according to the special features of the particular problem and the ingenuity of the designer. It is shown that the use of a nonlinear reactor in series with the thyristor provides advantages in some surge suppression networks, and a design technique is presented for these reactors. Characteristics of a basic damping circuit are presented in the form of non-dimensional design curves, and a relationship is established between the losses of a surge suppression network and the thyristor
and
capabilities.
and
capabilities.Keywords
Saturable-core reactors; Thyristor controls; Thyristor converters; Thyristor switches; Current density; Damping; Diodes; Frequency; Impedance; Inductors; Manufacturing; Surge protection; Thyristor circuits; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1967.1066053