DocumentCode :
1036144
Title :
Harmonic Index----A Tool for Transformer Audio Noise Investigation
Author :
Mutschler, W.H. ; Madden, T.F.
Author_Institution :
Allis-Chalmers Manufacturing Company, Pittsburgh, Pa.
Volume :
69
Issue :
1
fYear :
1950
Firstpage :
115
Lastpage :
120
Abstract :
The harmonic index is the decibel difference between the noise level obtained with the flat weighting and the noise level obtained with the 40-decibel weighting. It is a qualitative measure of the harmonic content of the noise measured at a given point. The harmonic index was introduced several years ago,1 but it has not realized the consideration which it merits. It is the purpose of this paper to demonstrate the value of the harmonic index when used in conjunction with the flat weighting measurements as a simple approach to the problem of evaluating the complex structures of the transformer.
Keywords :
Acoustic noise; Magnetic cores; Magnetic flux; Magnetostriction; Noise generators; Noise level; Noise measurement; Power generation economics; Power transformers; Steel;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1950.5060128
Filename :
5060128
Link To Document :