• DocumentCode
    1036224
  • Title

    The application of the scanning electron microscope to the development of high-reliability semiconductor products

  • Author

    Cox, Ronald H. ; Crosthwait, Delbert L., Jr. ; Dobrott, Robert D.

  • Author_Institution
    Texas Instruments Inc., Dallas, Tex.
  • Volume
    16
  • Issue
    4
  • fYear
    1969
  • fDate
    4/1/1969 12:00:00 AM
  • Firstpage
    376
  • Lastpage
    380
  • Abstract
    Examples are given which illustrate the wide range of applicability of the scanning electron microscope to the processing of high reliability semiconductor products. The three areas selected for presentation are devitrifying solder glass seals for hermetic packages, voltage contrast examination of biased integrated circuits, and metallization corrosion problems encountered in processing technology. The scanning electron microscope gave useful information quickly, and, in some cases, it gave answers that other methods were unable to supply.
  • Keywords
    Corrosion; Glass; Integrated circuit metallization; Integrated circuit packaging; Integrated circuit reliability; Scanning electron microscopy; Seals; Semiconductor device packaging; Semiconductor device reliability; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1969.16760
  • Filename
    1475802