DocumentCode
1037841
Title
Multistep Resistor Control of Switching Surges
Author
Colclaser, R. Gerald, Jr. ; Wagner, Charles L. ; Donohue, Edward P.
Author_Institution
Westinghouse Electric Corporation
Issue
7
fYear
1969
fDate
7/1/1969 12:00:00 AM
Firstpage
1022
Lastpage
1028
Abstract
For system voltages above 500 kV the conventional one-step resistor cannot limit switching surge overvoltages to the desired level of 1.7 per unit or less. This paper presents the results of an analog computer study of four possible methods of controlling switching surge overvoltages with a breaker and/or resistors. The alternatives studied include synchronous control of closing without a resistor, a ganged three-resistor breaker, a ganged two-resistor breaker, and a controlled closing two-resistor breaker. Overvoltage limits and breaker timing criteria are obtained for each alternative.
Keywords
Analog computers; Insulation; Lightning; Power transmission lines; Resistors; Surges; Switchgear; Timing; Transient analysis; Voltage;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1969.292501
Filename
4073939
Link To Document