DocumentCode
1038629
Title
A 2,000,000-Kva Transformer Core
Author
Sealey, W.C.
Author_Institution
Allis-Chalmers Manufacturing Company, Milwaukee, Wis.
Volume
70
Issue
1
fYear
1951
fDate
7/1/1951 12:00:00 AM
Firstpage
8
Lastpage
11
Abstract
The largest 60-cycle transformer core ever made now is in successful operation on a 300,000,000-volt betatron. If this core were used for an oil immersed power transformer, windings for continuous operation at 2,000,000 kva could be placed on it. Construction of this core is a demonstration of the feasibility of constructing transformers many times as large as those now being built. The advantages of larger transformers are lower cost per kilovolt-ampere and less loss per kilovolt-ampere transformed resulting in higher efficiency. The present limitation in the size of transformers is shipping clearances. When transformers larger than those which can be shipped are needed, they can be constructed by assembling them in the field using construction and methods similar to those employed for this large core.
Keywords
Assembly; Design engineering; Ducts; Lamination; Magnetic cores; Oil insulation; Power engineering and energy; Power transformers; Steel; Transformer cores;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1951.5060364