DocumentCode :
1038690
Title :
Investigation of Optimum Electrode Locations by Using an Automatized Surface Electromyography Analysis Technique
Author :
Nishihara, Ken ; Kawai, Hisashi ; Gomi, Toshiaki ; Terajima, Miho ; Chiba, Yu
Author_Institution :
Saitama Prefectural Univ., Koshigaya
Volume :
55
Issue :
2
fYear :
2008
Firstpage :
636
Lastpage :
642
Abstract :
Identification of the innervation zone is widely used to optimize the accuracy and precision of noninvasive surface electromyography (EMG) signals because the EMG signal is strongly influenced by innervation zones. However, simply structured fusiform muscle, such as biceps brachii muscle, has been employed mainly due to the simplicity with which the propagation from raw EMG signals can be observed. In this study, the optimum electrode location (OEL), free from innervational influence, was investigated by the propagation pattern of action potentials for brachii muscles and more complicated deltoid muscle structures using an automatized signal analysis technique. The technique employed newly developed computer software with additional clinical uses and minimized subjective differences. EMG signals were recorded using surface array electrodes during voluntary isometric contractions obtained from 12 healthy male subjects. Peaks in EMG signals were detected and averaged for each muscle. The propagation patterns and OEL were examined from biceps brachii muscles for all subjects and from deltoid muscles for seven subjects. The estimated locations were partially confirmed by comparing the root mean squares of the EMG signals. These results show that propagation patterns and OEL could be estimated simply and automatically even from the surface EMG signals of deltoid muscles.
Keywords :
bioelectric potentials; electromyography; medical signal detection; medical signal processing; EMG signal detection; action potential pattern; automatized signal analysis technique; biceps brachii muscle; computer software; deltoid muscle structures; innervation zone identification; noninvasive surface electromyography analysis technique; optimum electrode locations; root mean squares; structured fusiform muscle; surface array electrodes; voluntary isometric contractions; Electrodes; Electromyography; Medical treatment; Muscles; Root mean square; Signal analysis; Signal detection; Signal processing; Software; Tendons; Electromyography (EMG); innervation zone; propagation pattern; surface array electrodes; Action Potentials; Algorithms; Artificial Intelligence; Diagnosis, Computer-Assisted; Electrodes; Electromyography; Humans; Muscle, Skeletal; Pattern Recognition, Automated; Reproducibility of Results; Sensitivity and Specificity;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2007.912673
Filename :
4432750
Link To Document :
بازگشت