• DocumentCode
    1038772
  • Title

    Basic Characteristics of Corona Detector Calibrators

  • Author

    Mole, George

  • Author_Institution
    Electrical Research Association
  • Issue
    2
  • fYear
    1970
  • Firstpage
    198
  • Lastpage
    204
  • Abstract
    Accuracy of measurement of corona magnitude depends on the use of a calibrator to produce a stepwave that simulates the corona transient. The maximum permissible rise time, the minimum permissible decay time, and the minimum permissible repetition period have, been established by calculation and confirmed by experiment. The results may be used for drafting specifications for corona calibrators.
  • Keywords
    Circuit testing; Corona; Coupling circuits; Detectors; Electrical resistance measurement; Energy measurement; Frequency; Insulation; Q measurement; Technical drawing;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1970.292752
  • Filename
    4074037