The forward voltage technique to measure junction temperatures of ac operating triacs
Author
Tserng, Hua Quen ; Plumlee, Hubert R.
Author_Institution
Texas Instruments Incorporated, Dallas, Tex.
Volume
17
Issue
9
fYear
1970
fDate
9/1/1970 12:00:00 AM
Firstpage
755
Lastpage
761
Abstract
The forward voltage drop Vf of an ac operating triac can be employed to indicate its junction temperature. The Vf , for a constant test current, is shown to decrease linearly with increasing temperature over the range of 20 to 125°C with measured slopes between -1.4 to -1.6 mV/°C. A sampling current must be used at the end of an applied power pulse and the cooling of the triac which takes place during the delay in measurement is taken into account by an extrapolation procedure. The indicated temperature using the Vf method is in excellent agreement With the maximum temperature measured with an infrared microradiometer at the surface of the active region of the triac. The Vf technique requires a special power test circuit which is described. This technique provides an accurate indication of the maximum operating temperature and requires calibration of only a few triacs. Triac manufacturers can use the Vf technique to accurately measure the thermal performance of their triacs and to screen production to eliminate marginal devices.
Keywords
Circuit testing; Cooling; Current measurement; Delay; Pulse measurements; Sampling methods; Temperature distribution; Temperature measurement; Thyristors; Voltage measurement;
fLanguage
English
Journal_Title
Electron Devices, IEEE Transactions on
Publisher
ieee
ISSN
0018-9383
Type
jour
DOI
10.1109/T-ED.1970.17069
Filename
1476253
Link To Document