• DocumentCode
    1039165
  • Title

    Forced-Cooling Model Tests

  • Author

    Zanona, Aldo ; Williams, J.L., Jr.

  • Author_Institution
    Transmission Engineering Department, Commonwealth Edison Company
  • Issue
    3
  • fYear
    1970
  • fDate
    3/1/1970 12:00:00 AM
  • Firstpage
    491
  • Lastpage
    503
  • Abstract
    This paper describes the forced cooling of a model of a pipe-type cable circuit, utilizing mechanical refrigeration to cool the pipe-filling oil. Measured oil film thermal resistances and oil chiller performance are reported. Two pipe-filling oils were tested, a high- viscosity oil normally used for pipe-type cable and an experimental low-viscosity polybutene. The test results are expected to have an important effect on the design of future field installations of forced- cooled pipe-type cable circuits.
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1970.292541
  • Filename
    4074078