Abstract :
In selecting parameters for large hydropower generating units such as those for the Grand Coulee Third Powerplant, control characteristics to satisfy power system needs can strongly influence economics of the design. The needs for abnormal mechanical inertia and expensive reduction of the penstock water starting time are shown to be mitigated by refinement of governor characteristics. This paper describes selection of controllability to meet power system needs, relation of controllability to mechanical inertia and the penstock time constant to facilitate economic proportioning, influence of the governing system and its refinement with several new features for improved performance.
Keywords :
Character generation; Control systems; Controllability; Hydroelectric power generation; Power generation; Power generation economics; Power system control; Power system economics; Power systems; Water;