DocumentCode :
1042483
Title :
Three-phase three-level voltage source inverter with low switching frequency based on the two-level inverter topology
Author :
Mahrous, E.A. ; Rahim, N.A. ; Hew, W.P.
Author_Institution :
Fac. of Eng., Univ. of Malaya, Kuala Lumpur
Volume :
1
Issue :
4
fYear :
2007
fDate :
7/1/2007 12:00:00 AM
Firstpage :
637
Lastpage :
641
Abstract :
A new configuration of the three-phase three-level voltage source inverter has been presented. The proposed inverter is based on the two-level inverter. The inverter is built of one two-level conventional inverter, an auxiliary circuit which comprises of three bidirectional switches, and two bulk capacitor banks. A selected harmonic elimination control scheme is employed to achieve lower harmonic contents in the inverter output waveforms. Two-level inverter switches operate at the line power frequency (50 Hz) whereas the auxiliary circuit switches operate at twice line power frequency (100 Hz). To validate the proposed inverter, a low power prototype inverter has been designed and implemented; analytical, simulation and experimental results have been provided.
Keywords :
capacitors; harmonics suppression; invertors; switching networks; bulk capacitor banks; harmonic elimination control; low switching frequency; three-phase three-level voltage source inverter; twice line power frequency; two-level inverter topology;
fLanguage :
English