Abstract :
This paper describes frequency response tests run on one of Ohio Edison Company´s large supercritical once-through units. It briefly covers the reason for testing, the apparatus, the procedure and the results. A discussion of the unit control aspects as they apply to the tests is also included.
Keywords :
Boilers; Centralized control; Control systems; Error correction; Frequency response; Pressure control; Temperature control; Testing; Turbines; Valves;