DocumentCode :
1043418
Title :
Quasi-Peak Measurements and their Objective Correlation to Acoustical Annoyance of Corona Radio Noise
Author :
Khalifa, Mohammad M. ; Kamal, Ahmad A. ; Habib, Sirag E. ; El-bedwaihy, Sayed A. ; Fahmy, Gamal S. ; Hassan, Mohammad A.
Author_Institution :
Electrical Engineering Department, Cairo University
Issue :
4
fYear :
1971
fDate :
7/1/1971 12:00:00 AM
Firstpage :
1830
Lastpage :
1837
Abstract :
The levels of annoyance to radio reception caused by ac and dc coronas are calculated using the AF power spectra measured at the AF output of a radio-noise meter. The radio annoyance levels. (RAL) and the AF powers are compared with the corresponding quasi-peak readings. The lack of direct correspondence is ascribed to the fact that the QP readings are not sensitive to the randomness in the corona pulse repetition rate which strongly affects both the AF power spectrum and the RAL of corona.
Keywords :
Acoustic measurements; Acoustic noise; Corona; Frequency measurement; Noise level; Noise measurement; Quadratic programming; Radio frequency; Testing; Voltage;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1971.293176
Filename :
4074531
Link To Document :
بازگشت