• DocumentCode
    1043456
  • Title

    Sensitivity measurement of a 10.6-µm parametric upconverter

  • Author

    Chiou, W. ; Klinger, Y. ; Arams, F.

  • Volume
    19
  • Issue
    7
  • fYear
    1972
  • fDate
    7/1/1972 12:00:00 AM
  • Firstpage
    894
  • Lastpage
    894
  • Abstract
    The sensitivity of a parametric upconverter for the detection of 10.6-µm radiation was measured. 10.6-µm radiation was mixed with the 1.06 µm beam of an Nd :YAG laser in properly oriented single-crystal proustite. The upconverted output at 0.967 µm was then detected by an S-1 photomultiplier tube. NEP of 1.1×10-9W . s½was measured.
  • Keywords
    Infrared detectors; Laser excitation; Laser noise; Photomultipliers; Photonic crystals; Power lasers; Power measurement; Pulse measurements; Pump lasers; Signal to noise ratio;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1972.17515
  • Filename
    1476986