Title :
Reliable link initialization procedures
Author :
Baratz, Alan E. ; Segall, Adrian
Author_Institution :
IBM Thomas J. Watson Res. Center, Yorktown Heights, NY, USA
fDate :
2/1/1988 12:00:00 AM
Abstract :
It is known that HDLC (high-level data link control) and other bit-oriented DLC procedures ensure data transmission reliability across noisy transmission media, provided that all frame errors are detected and the link processes are synchronized at initialization. It is shown that the HDLC initialization procedure does not ensure synchronization and allows inadvertent loss of data. Several link initialization procedures are proposed and it is proved that they do ensure synchronization
Keywords :
error detection; reliability; synchronisation; telecommunication channels; telecommunication links; HDLC; bit-oriented DLC procedures; data loss; data transmission reliability; error detection; frame errors; high-level data link control; link initialization procedures; link processes; noisy transmission media; synchronisation; Communications Society; Conferences; Cyclic redundancy check; Data communication; Delay; Error correction; Hardware; Power system reliability; Protection; Protocols;
Journal_Title :
Communications, IEEE Transactions on