Title :
Project UHV Test Line Research on the Corona Performance of a Bundle Conductor at 1000 kV
Author :
Anderson, John G. ; Zaffanella, Luciano E.
Author_Institution :
General Electric Company
Abstract :
A bundle of 4 subconductors 2-in (5.08 cm) in diameter was tested on the Project UHV single-phase test line. Radio noise, corona loss, audible noise, electrostatic field effects were continuously measured in order to investigate the effects of weather variables. Translation of the results to a 1000-kV, 3-phase line shows that audible noise will be the main obstacle to the use of this bundle.
Keywords :
Acoustic noise; Antenna measurements; Capacitors; Conductors; Corona; Instruments; Loss measurement; Noise measurement; Testing; Voltage;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1972.293334