DocumentCode
1047349
Title
Errors in the power loss measured in clockwise and anticlockwise rotational magnetisation. Part 1: Mathematical study
Author
Zurek, S. ; Meydan, T.
Author_Institution
Wolfson Centre for Magnetics, Cardiff Univ., UK
Volume
153
Issue
4
fYear
2006
fDate
7/7/2006 12:00:00 AM
Firstpage
147
Lastpage
151
Abstract
It is well known that the rotational power loss differs if the flux vector is rotated in either a clockwise or an anticlockwise rotation direction. An analysis is presented that shows that averaging the clockwise and anticlockwise values introduces an additive error that is dependent on the angular misalignment between the measuring sensors. Equations to minimise this error are presented and validated by application to experiments on electrical sheet steel.
Keywords
fluxgate magnetometers; loss measurement; magnetic sensors; magnetisation; power measurement; angular misalignment; anticlockwise rotational magnetization; clockwise rotational magnetization; electrical sheet steel; flux vector; power loss measurement; rotational power loss;
fLanguage
English
Journal_Title
Science, Measurement and Technology, IEE Proceedings -
Publisher
iet
ISSN
1350-2344
Type
jour
DOI
10.1049/ip-smt:20050072