DocumentCode
1047472
Title
Starting Characteristics and Control of Polyphase Squirrel-Cage Induction Motors
Author
Norman, Horace M.
Author_Institution
Design Engineer, Westinghouse Electric & Manufacturing Co., East Pittsburgh, Pa.
fYear
1926
Firstpage
369
Lastpage
382
Abstract
In the application of squirrel-cage induction motors to such severe service as frequent start-and-stop or frequent plugging operation, it is desirable to know how much loss the motor will be required to dissipate, plugging being understood as changing the motor from any speed in one direction to any speed in the opposite direction, by reversing the rotation of the field only. The subject of starting loss is also of interest from the control standpoint??such as the application of auto-transformers for starting purposes, or where an external resistance is inserted in the primary as is done in the control of elevator motors. Consideration is given to the part that the primary and secondary resistance and the total reactance play in the determination and the manipulation of the starting losses; and, as it is true that in many applications the time spent in accelerating the rotor from. rest is useless from the production standpoint, consideration is given to the value of secondary resistance that will give minimum starting time for a given field strength. This involves a method for the determination of the time taken to attain a given speed in general. There are many cases where a motor has already been designed and tested, and is about to be applied on a given job where the cycle of operation is known and includes either starting and stopping or plugging.
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1926.5061230
Filename
5061230
Link To Document