• DocumentCode
    1047676
  • Title

    High resolution positron emission tomography with a prototype camera based on solid state scintillation detectors

  • Author

    Lecomte, R. ; Cadorette, J. ; Jouan, A. ; Heon, M. ; Rouleau, D. ; Gauthier, G.

  • Author_Institution
    Dept. of Nucl. Med. & Radiol., Sherbrooke Univ., Que., Canada
  • Volume
    37
  • Issue
    2
  • fYear
    1990
  • fDate
    4/1/1990 12:00:00 AM
  • Firstpage
    805
  • Lastpage
    811
  • Abstract
    The prototype of a high-resolution PET (positron emission tomography) camera consisting of two opposite arrays of detectors with independent solid-state readout was built and tested. The basic detector unit is the RCA C30994 detector module consisting of two 3-mm×5-mm×20-mm BGO scintillators, each coupled to one silicon avalanche photodiode. The two-dimensional stacking capability of the module allows a high-resolution multiring detection system to be assembled without crystal coding. The prototype was used to simulate a 31-cm-diameter dual ring tomograph suitable for animal studies. Coincident detector pair resolution was measured, and the contributions to resolution loss were estimated using a platinum-sheathed 0.75 mm 68Ge line source. The intrinsic resolution is 1.9 mm FWHM (full width at half maximum), 3.5 mm FWTM at the center of the field. The reconstructed point spread function resolution in a stationary mode is 2.3 mm FWHM at the center and 3.1 mm FWHM (tangential), 3.9 mm FWHM (radial) 5 cm from the center. The axial resolution is less than 3.5 mm FWHM throughout the field. The ring sensitivity for an animal system is 67 kcps/mCi in air for an axial line source and 3.3 kcps/μCi/ml for a 10-cm-diameter cylinder of 22Na solution
  • Keywords
    computerised tomography; radioisotope scanning and imaging; scintillation counters; BGO scintillators; Bi4Ge3O12; PET; RCA C30994 detector module; Si; avalanche photodiode; axial resolution; intrinsic resolution; multiring detection system; positron emission tomography; reconstructed point spread function resolution; ring sensitivity; solid-state readout; two-dimensional stacking capability; Animals; Avalanche photodiodes; Cameras; Detectors; Positron emission tomography; Prototypes; Sensor arrays; Silicon; Solid state circuits; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.106719
  • Filename
    106719