• DocumentCode
    1049049
  • Title

    Condenser Shunt for Measurement of High-Frequency Currents of Large Magnitude

  • Author

    Nyman, Alexander

  • Author_Institution
    Consulting Engineer, Dubilier Condenser Corporation, New York, N. Y.
  • fYear
    1927
  • Firstpage
    488
  • Lastpage
    491
  • Abstract
    The necessity for an accurate ammeter for large high-frequency currents is pointed out. A new device consisting of a large condenser in parallel with a small condenser, and the latter carrying the current to a small thermocouple ammeter, is described. A device of this nature can be made very accurate; in fact, comparable in accuracy to any available standards. The construction of the device includes provisions for restricting the electrostatic and electromagnetic field, due to large current, the reduction of distributed inductance and capacity, and a provision to prevent the resonance effect of high harmonics of the operating current. Provisions are also made for locating the measuring instrument at a distance from the circuit. Large ratings are possible by connecting a number of condenser blocks in parallel.
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1927.5061380
  • Filename
    5061380