• DocumentCode
    1049240
  • Title

    Immediate Warning of Local Overheating in Electric Machines by the Detection of Pyrolysis Products

  • Author

    Carson, C.C. ; Barton, S.C. ; Echeverria, F.S.

  • Author_Institution
    Materials and Processes Laboratory General Electric Company Generator Department
  • Issue
    2
  • fYear
    1973
  • fDate
    3/1/1973 12:00:00 AM
  • Firstpage
    533
  • Lastpage
    542
  • Abstract
    A device employing an ion chamber has been developed for the sensitive, reliable, and very rapid detection of local ovetheatingin a gas-cooled electric machine before extensive damage can result. The device detects the presence of pyrolysis products generated by the thermal decomposition of organic materials such as insulations and polymers. The pyrolysis products include particles of the size of condensation nuclei (about 0.001 to 0.1 microns), and smaller, which have such a pronounced effect on the ion current in the ion chamber that a definite signal is obtained from a hot spot as small as one square inch in area in a large hydrogen-cooled generator. A considerable amount of test and operating experience has been acquired.
  • Keywords
    Coatings; Detectors; Electric machines; Laboratories; Lamination; Monitoring; Stator cores; Surface resistance; Teeth; Temperature;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1973.293754
  • Filename
    4075108