DocumentCode
1049240
Title
Immediate Warning of Local Overheating in Electric Machines by the Detection of Pyrolysis Products
Author
Carson, C.C. ; Barton, S.C. ; Echeverria, F.S.
Author_Institution
Materials and Processes Laboratory General Electric Company Generator Department
Issue
2
fYear
1973
fDate
3/1/1973 12:00:00 AM
Firstpage
533
Lastpage
542
Abstract
A device employing an ion chamber has been developed for the sensitive, reliable, and very rapid detection of local ovetheatingin a gas-cooled electric machine before extensive damage can result. The device detects the presence of pyrolysis products generated by the thermal decomposition of organic materials such as insulations and polymers. The pyrolysis products include particles of the size of condensation nuclei (about 0.001 to 0.1 microns), and smaller, which have such a pronounced effect on the ion current in the ion chamber that a definite signal is obtained from a hot spot as small as one square inch in area in a large hydrogen-cooled generator. A considerable amount of test and operating experience has been acquired.
Keywords
Coatings; Detectors; Electric machines; Laboratories; Lamination; Monitoring; Stator cores; Surface resistance; Teeth; Temperature;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1973.293754
Filename
4075108
Link To Document