DocumentCode
1049314
Title
Nonlinear Theory of Turboalternators Part II. Load Dependent Synchronous Reactances
Author
Fuchs, Ewald F. ; Erdelyi, Edward A.
Author_Institution
University of Colorado
Issue
2
fYear
1973
fDate
3/1/1973 12:00:00 AM
Firstpage
592
Lastpage
599
Abstract
The method in Ref. [1] is used to determine synchronous reactances for the turbogenerator at operating conditions in Part I [2]. The influence of saturation on the direct and quadrature reactances is studied and the difficulties caused by linear parameters in nonlinear theory are discussed. A modified phasor-diagram taking the small angles ¿d and ¿q into account is developed. The results are given for a Westinghouse Electric Corp. 200 MVA, 15 kV, wye-connected, four-pole, 50 Hz generator. Available test data are compared with computations.
Keywords
Alternators; Machinery; Power & Energy Society; Power engineering and energy; Power engineering computing; Power system analysis computing; Power systems; Printing; Testing; Turbogenerators;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1973.293762
Filename
4075115