DocumentCode
104993
Title
Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Author
Boileau, Thierry ; Leboeuf, Nicolas ; Nahid-Mobarakeh, B. ; Meibody-Tabar, Farid
Author_Institution
Groupe de Rech. en Electron. et en Electrotech. de Nancy, Univ. de Lorraine, Vandoeuvre, France
Volume
28
Issue
12
fYear
2013
fDate
Dec. 2013
Firstpage
5647
Lastpage
5654
Abstract
In this paper, a new technique for stator winding interturn fault detection in current-controlled permanent magnet synchronous machines is proposed. The method is based on online extraction of the second harmonic component of the voltage reference vector in the dq frame. It will be shown that the amplitude of this harmonic depends on the interturn fault severity and the fault detection is realized by comparing the magnitude of the control voltage second harmonic, derived using a proper time-domain transformation, to a predefined threshold. This is a low-cost method in CPU burden time. The experimental results show the validity of the proposed method.
Keywords
demodulation; electric current control; fault diagnosis; machine control; permanent magnet machines; stators; synchronous machines; voltage control; PMSM; control voltage; current control; online extraction; permanent magnet machine; second harmonic component; stator interturn fault detection; stator winding interturn fault detection; synchronous demodulation; synchronous machine; voltage reference vector; Circuit faults; Fault detection; Harmonic analysis; Insulation; Radio frequency; Stator windings; Voltage control; Fault diagnosis; health monitoring; interturn fault; permanent magnet synchronous machine (PMSM);
fLanguage
English
Journal_Title
Power Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0885-8993
Type
jour
DOI
10.1109/TPEL.2013.2254132
Filename
6484985
Link To Document