• DocumentCode
    104993
  • Title

    Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM

  • Author

    Boileau, Thierry ; Leboeuf, Nicolas ; Nahid-Mobarakeh, B. ; Meibody-Tabar, Farid

  • Author_Institution
    Groupe de Rech. en Electron. et en Electrotech. de Nancy, Univ. de Lorraine, Vandoeuvre, France
  • Volume
    28
  • Issue
    12
  • fYear
    2013
  • fDate
    Dec. 2013
  • Firstpage
    5647
  • Lastpage
    5654
  • Abstract
    In this paper, a new technique for stator winding interturn fault detection in current-controlled permanent magnet synchronous machines is proposed. The method is based on online extraction of the second harmonic component of the voltage reference vector in the dq frame. It will be shown that the amplitude of this harmonic depends on the interturn fault severity and the fault detection is realized by comparing the magnitude of the control voltage second harmonic, derived using a proper time-domain transformation, to a predefined threshold. This is a low-cost method in CPU burden time. The experimental results show the validity of the proposed method.
  • Keywords
    demodulation; electric current control; fault diagnosis; machine control; permanent magnet machines; stators; synchronous machines; voltage control; PMSM; control voltage; current control; online extraction; permanent magnet machine; second harmonic component; stator interturn fault detection; stator winding interturn fault detection; synchronous demodulation; synchronous machine; voltage reference vector; Circuit faults; Fault detection; Harmonic analysis; Insulation; Radio frequency; Stator windings; Voltage control; Fault diagnosis; health monitoring; interturn fault; permanent magnet synchronous machine (PMSM);
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2013.2254132
  • Filename
    6484985