Accurate Estimation of Low ( \\ll \\hbox {10}^{-8} \\Omega \\cdot \\hbox {cm}^{2}) Values of Specific Contact Resistivity
Author :
Bhaskaran, Madhu ; Sriram, Sharath ; Holland, Anthony S.
Author_Institution :
RMIT Univ., Melbourne
Volume :
29
Issue :
3
fYear :
2008
fDate :
3/1/2008 12:00:00 AM
Firstpage :
259
Lastpage :
261
Abstract :
Advancements in nanotechnology have created the need for efficient means of communication of electrical signals to nanostructures, which can be addressed using low resistance contacts. In order to study and estimate the resistance of such contacts or the resistance posed by the interface(s) in such contacts, accurate test structures and evaluation techniques need to be used. The resistance posed by an interface is quantified using its specific contact resistivity (SCR), and although multiple techniques have been utilized, inaccuracies of such techniques in measuring values of SCR lesser than ( < 10-8 Omega ldr cm2 ) have been reported. In this letter, an approach for estimating very low values of SCR (lower than the previously limiting ( < 10-8 Omega ldr cm2 )) using a cross Kelvin resistor test structure is demonstrated using aluminum to titanium silicide ohmic contacts, with a minimum estimated SCR value of 6.0 times 10-10 Omega ldr cm2.
Keywords :
contact resistance; electric resistance measurement; electrical resistivity; ohmic contacts; Al-TiSi2; accurate estimation; cross Kelvin resistor test structure; interface resistance; low resistance contacts; nanotechnology; ohmic contacts; specific contact resistivity; Contact resistance; cross Kelvin resistor (CKR); specific contact resistivity (SCR);
fLanguage :
English
Journal_Title :
Electron Device Letters, IEEE
Publisher :
ieee
ISSN :
0741-3106
Type :
jour
DOI :
10.1109/LED.2007.915378
Filename :
4441939
Link To Document :
بازگشت