DocumentCode
1050338
Title
Modelling the spatial response of a compensated density tool
Author
Petler, John S.
Author_Institution
BP Res., Sunbury-on-Thames, UK
Volume
37
Issue
2
fYear
1990
fDate
4/1/1990 12:00:00 AM
Firstpage
954
Lastpage
958
Abstract
The spatial response of a compensated spectral density tool has been studied by Monte Carlo modeling. The results show that the vertical resolution of the density measurement is independent of the formation characteristics. The radial depth of the measurement is shown to vary between the source and detector and also to depend on the formation density. The spatial resolution of the photoelectric measurement depends on the atomic number of the formation. The apparent location of a horizontal bed boundary is found to depend on the direction of approach to the density contrast
Keywords
Monte Carlo methods; chemical analysis by nuclear reactions and scattering; geophysical prospecting; geophysical techniques; Monte Carlo modeling; compensated density tool; compensated spectral density tool; horizontal bed boundary; photoelectric measurement; radial depth; spatial response; vertical resolution; Absorption; Atomic measurements; Calibration; Density measurement; Energy resolution; Monte Carlo methods; Particle measurements; Photonic crystals; Solid scintillation detectors; Spatial resolution;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.106742
Filename
106742
Link To Document