• DocumentCode
    1050854
  • Title

    Fascicular Perineurium Thickness, Size, and Position Affect Model Predictions of Neural Excitation

  • Author

    Grinberg, Yanina ; Schiefer, Matthew A. ; Tyler, Dustin J. ; Gustafson, Kenneth J.

  • Author_Institution
    Dept. of Biomed. Eng., Case Western Reserve Univ., Cleveland, OH
  • Volume
    16
  • Issue
    6
  • fYear
    2008
  • Firstpage
    572
  • Lastpage
    581
  • Abstract
    The number of applications using neural prosthetic interfaces is expanding. Computer models are a valuable tool to evaluate stimulation techniques and electrode designs. Although our understanding of neural anatomy has improved, its impact on the effects of neural stimulation is not well understood. This study evaluated the effects of fascicle perineurial thickness, diameter, and position on axonal excitation thresholds and population recruitment using finite element models and NEURON simulations. The perineurial thickness of human fascicles was found to be 3.0% plusmn 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter increased activation thresholds. The presence of a large neighboring fascicle caused a significant change in activation of a smaller target fascicle by as much as 80% plusmn 11% of the total axon population. Smaller fascicles were recruited at lower amplitudes than neighboring larger fascicles. These effects were further illustrated in a realistic model of a human femoral nerve surrounded by a nerve cuff electrode. The data suggest that fascicular selectivity is strongly dependent upon the anatomy of the nerve being stimulated. Therefore, accurate representations of nerve anatomy are required to develop more accurate computer models to evaluate and optimize nerve electrode designs for neural prosthesis applications.
  • Keywords
    finite element analysis; neurophysiology; prosthetics; NEURON simulations; axon population; fascicular perineurium; fascicular selectivity; finite element models; human femoral nerve; nerve anatomy; nerve cuff electrode; neural excitation; neural prosthesis applications; Anatomy; Application software; Electrodes; Finite element methods; Humans; Nerve fibers; Neurons; Predictive models; Prosthetics; Recruitment; Computer models; functional electrical stimulation; nerve cuff electrode; nerve fascicle; neuroanatomy; Action Potentials; Animals; Computer Simulation; Differential Threshold; Electric Stimulation; Electric Stimulation Therapy; Electrodes, Implanted; Femoral Nerve; Humans; Models, Neurological; Peripheral Nerves;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2008.2010348
  • Filename
    4731275