Title : 
The Interpretation of Corona and Dielectric Measurements on the Mica-Asphalt Insulation of a 30-Year-Old WaterWheel Generator at Grand Coulee Dam
         
        
            Author : 
Harrold, R.T. ; Fort, E.M. ; Goodwin, T.A.
         
        
            Author_Institution : 
Westinghouse Research Laboratories
         
        
        
        
        
        
            Abstract : 
It is important to have reliable field techniques for assessing the insulation quaility of large rotating machine stators in order to reveal any defects which could lead to a winding failure in service. Toward this objective, a variety of nondestructive measurements of internal discharges (corona) have been applied and compared on an old mica-asphalt insulated generator. Extensive field measurements of RIV corona and integrated corona charge per cycle (related to power factor tip-up) are reported and interpreted, and verified by tests on coils returned to the laboratory.
         
        
            Keywords : 
Charge measurement; Corona; Current measurement; Dielectric measurements; Dielectrics and electrical insulation; Machine windings; Power measurement; Reactive power; Rotating machines; Stator windings;
         
        
        
            Journal_Title : 
Power Apparatus and Systems, IEEE Transactions on
         
        
        
        
        
            DOI : 