• DocumentCode
    1051809
  • Title

    A Study on the Measurement Technique of Image Retention in AC Plasma Display Panels

  • Author

    Do, Yun Seon ; Kim, Sang Ho ; Choi, Kyung Cheol

  • Author_Institution
    Display & Nano Devices Res. Team, DGIST, Daegu
  • Volume
    4
  • Issue
    2
  • fYear
    2008
  • fDate
    6/1/2008 12:00:00 AM
  • Firstpage
    238
  • Lastpage
    244
  • Abstract
    A technique for quantitatively measuring the image retention is suggested. This work focuses on dark image retention, which occurs during the reset period. To investigate the dark image retention phenomenon, characteristics of reset discharge were observed in accordance with the slope of the reset pulse. The temporal behaviors of luminance, chromatistic values, and infra red emission were observed with the black-level image after a five-minute repeatedly strong discharge. The image retention time of the luminance and chromatistic values increased with a decrease in the rising time of the reset ramp pulse. For the case of infrared (IR) emission, there was no clear tendency, in contrast with the image retention or temporal image sticking phenomenon. The results indicate that measurement of the temporal behaviors of luminance and chromatistic values provide suitable measurement for investigating the image retention in AC plasma display panels (PDPs), whereas the IR emission does not provide a useful guide in this regard.
  • Keywords
    brightness; plasma displays; AC plasma display panels; black-level image; chromatistic values; dark image retention phenomenon; infra red emission; luminance values; measurement technique; reset discharge characteristics; Image retention; infrared emission; plasma display panel (PDP); reset discharge; temporal image sticking;
  • fLanguage
    English
  • Journal_Title
    Display Technology, Journal of
  • Publisher
    ieee
  • ISSN
    1551-319X
  • Type

    jour

  • DOI
    10.1109/JDT.2007.914039
  • Filename
    4443880