• DocumentCode
    1052193
  • Title

    Area Effect of Electrical Breakdown in Compressed SF6

  • Author

    Nitta, T. ; Yamada, N. ; Fujiwara, Y.

  • Author_Institution
    Mitsubishi Electric Corporation
  • Issue
    2
  • fYear
    1974
  • fDate
    3/1/1974 12:00:00 AM
  • Firstpage
    623
  • Lastpage
    629
  • Abstract
    This paper presents experimental results on the statistical properties of ac and dc breakdown field strength of compressed SF6. The experiment is performed on four gaps of different electrode area, ranging from 0.2 cm2 to 3000 cm2. Patterns of breakdown characteristics are classified into four categories depending on the type of distribution and the characteristics of conditioning effect. The criterion of the transition of these categories are discussed quantitatively.
  • Keywords
    Coaxial components; Electric breakdown; Electrodes; Engine cylinders; Rough surfaces; Steel; Sulfur hexafluoride; Surface finishing; Surface roughness; Testing;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1974.294024
  • Filename