DocumentCode
1052337
Title
Real-time rectilinear 3-D ultrasound using receive mode multiplexing
Author
Yen, Jesse T. ; Smith, Stephen W.
Author_Institution
Dept. of Biomed. Eng., Univ. of Southern California, Los Angeles, CA, USA
Volume
51
Issue
2
fYear
2004
Firstpage
216
Lastpage
226
Abstract
In previous work, we developed two generations of a real-time rectilinear volumetric scanner operating at 5 MHz for abdominal, breast, or vascular imaging using a Mills cross two-dimensional (2-D) array and a rectilinear periodic 2-D array. To improve spatial resolution performance and sensitivity, we developed a new design using 4:1 receive mode multiplexing. With 4:1 multiplexing, the new 65,000 element 2-D array has 4/spl times/256=1024 receivers so that 256 receivers can be used on any image line. The two major benefits of using receive mode multiplexing are an increase in receive sensitivity due to a greater number of receive elements, and a decrease in grating lobe and clutter levels due to increased receive element density. Theoretical simulations and analysis show an increase of about 13 dB in sensitivity compared to our previous work. With these encouraging results, a new 65,000 element 5-MHz, 2-D array having 1024 receivers and 169 transmitters was prototyped. In addition, the multiplexer and control circuitry were designed, built, and interfaced with both the transducer and volumetric scanner. Images of tissue-mimicking phantoms and in vivo targets were obtained. Using a spherical cyst phantom, experimental results showed a+12 dB improvement in signal-to-noise ratio and a+6 dB improvement in contrast compared to our previous work.
Keywords
acoustic receivers; biological tissues; biomedical ultrasonics; multiplexing; phantoms; transmitters; ultrasonic transducer arrays; 5 MHz; Mills cross two dimensional 2D array; abdominal imaging; breast imaging; clutter levels; control circuitry; grating lobe; multiplexer; real time rectilinear 3-D ultrasound; receive mode multiplexing; sensitivity; signal to noise ratio; spatial resolution; spherical cyst phantom; tissue mimicking phantoms; transmitters; vascular imaging; vivo targets; volumetric scanner; Abdomen; Analytical models; Brain modeling; Breast; Gratings; Imaging phantoms; Milling machines; Spatial resolution; Two dimensional displays; Ultrasonic imaging; Adult; Blood Vessels; Equipment Design; Equipment Failure Analysis; Humans; Image Enhancement; Imaging, Three-Dimensional; Liver; Male; Neoplasms; Online Systems; Phantoms, Imaging; Signal Processing, Computer-Assisted; Transducers; Ultrasonography;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2004.1320770
Filename
1320770
Link To Document