Low-Stress Thermosonic Copper Ball Bonding
Author :
Shah, Aashish ; Mayer, Michael ; Zhou, Y. Norman ; Hong, S.J. ; Moon, J.T.
Author_Institution :
Center for Adv. Mater. Joining, Univ. of Waterloo, Waterloo, ON, Canada
Volume :
32
Issue :
3
fYear :
2009
fDate :
7/1/2009 12:00:00 AM
Firstpage :
176
Lastpage :
184
Abstract :
Thermosonic ball bonding processes on test chips with Al metallized bonding pads are optimized with one Au and two Cu wire types, all 25 mum diameter, obtaining average shear strengths of more than 120 MPa. The process temperature is ~110degC. Ball bonds made with Cu wire show at least 15% higher shear strength than those made with Au wire. The estimated maximum shear strength cpk value determined for Cu ball bonding (cpk = 3.7 plusmn 1.2) is almost 1.5 times as large as that of the Au ball bonding process (cpk = 2.3 plusmn 0.9), where LSL is 65.2 MPa. However, the ultrasound level required for Cu is approximately 1.3 times than that required for Au. Consequently, about 30% higher ultrasonic forces induced to the bonding pad are measured using integrated real-time microsensors. The accompanying higher stresses increase the risk of under-pad damage. One way to reduce ultrasonic bonding stresses is by choosing the softer of the two Cu wire types, resulting in a measured ultrasonic force reduction of about 5%. A second way is to reduce the ultrasound level. While this causes the average shear strength to fall by 15%, the ultrasonic force falls by 9%. The cpk value does not change significantly, suggesting that a successful Cu ball bonding operation can be run with about 0.9 times the conventionally optimized ultrasound level. The process adjusted in this way reduces the extra stress observed with Cu wire compared to that observed with Au wire by 42%.
Keywords :
aluminium; bonding processes; copper; gold; integrated circuit packaging; metallisation; semiconductor device packaging; ultrasonics; wires (electric); Al-Cu-Au; aluminium metallisation bonding pads; copper wire; gold wire; low-stress thermosonic copper ball bonding; shear strength; size 25 mum; ultrasonic force; ultrasound level; Bonding stress; microsensors; process optimization; thermosonic copper wire bonding; ultrasound; underpad damage;
fLanguage :
English
Journal_Title :
Electronics Packaging Manufacturing, IEEE Transactions on
Publisher :
ieee
ISSN :
1521-334X
Type :
jour
DOI :
10.1109/TEPM.2009.2019123
Filename :
5062296
Link To Document :
بازگشت