Title :
Class IE Cables for Nuclear Power Generating Stations
Author :
McIlveen, E.E. ; Garrison, V.L. ; Dobrowolski, G.T.
Author_Institution :
The Okonite Company
fDate :
7/1/1974 12:00:00 AM
Abstract :
With the publication of IEEE Guide P 383 For Qualification Testing, it is appropriate to present typical data relating-to this document, and to briefly discuss its significance. Designed life performance for nuclear stations must be predicated for the most part on test data obtained from cable systems under simulated environmental conditions which are peculiar to this application. This paper presents data in the areas of (1) long time exposure to moisture at elevated temperature, (2) air oven heat aging, (3) simulated reactor radiation during normal operation as well as during and after a design basis event, and (4) flame testing of cables.
Keywords :
Aging; Cables; Life testing; Moisture; Nuclear power generation; Ovens; Power generation; Qualifications; System testing; Temperature;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1974.294058