• DocumentCode
    1053828
  • Title

    Nonlinear Salient Pole Alternator Subtrannsient Reactances and Damper Winding Currents

  • Author

    Fuchs, E.F. ; Erdélyi, E.A.

  • Author_Institution
    Kraftwerk Union AG.
  • Issue
    6
  • fYear
    1974
  • Firstpage
    1871
  • Lastpage
    1892
  • Abstract
    In the subtransient analysis of salient pole alternators the reactances X11d and X11q are generally assumed to be constants. In saturated alternators these reactances are in reality functions of the pre-transient load and saturationix This gaper is an extension of former papers by Fuchs, et it dealing with steady state, and transient reactances. The methods used are the same as in [1] and [2] with the addition of damper windings effects. Notations not explained here are those of Concordia4 and of Fuchs3. The analysis is applied to a G. E. alternator with the following name-plate data: 82.5 MVA, 16.5 kV, wye-connected, 40 poles and 60 Hz, described in [1].
  • Keywords
    Alternators; Couplings; Footwear; Impedance; Machinery; Magnetic circuits; Nonlinear equations; Power & Energy Society; Printing; Stators;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1974.293840
  • Filename
    4075559