Abstract
A description is presented of the control system for the automatic control of a very large dual-wave Michelson interferometer to be used in the VIRGO experiment, a gravitational wave search in the 10-3000-Hz band. The system is mainly based on a VME bus architecture, for the local controls, on which numeric control systems based on digital filters are implemented. The control systems are described along with the way they are linked together to form the global control system, in a hierarchical configuration
Keywords
astronomical instruments; computerised control; gravitational experiments; gravitational waves; light interferometers; physical instrumentation control; physics computing; 10 to 3000 Hz; VIRGO experiment; VME bus architecture; automatic alignment; automatic control; control system; digital filters; global control system; gravitational wave search; hierarchical configuration; local controls; numeric control systems; very large dual-wave Michelson interferometer; Antenna measurements; Automatic control; Buildings; Computerized monitoring; Control systems; Data acquisition; Laser stability; Mirrors; Optical attenuators; Optical noise;