• DocumentCode
    1055885
  • Title

    Pulse emission and extended life testing of the tungstate cathode

  • Author

    Smith, Bernard ; Newman, Albert

  • Author_Institution
    US Army Electronics Technology and Devices Laboratory (ECOM), Fort Monmouth, NJ
  • Volume
    24
  • Issue
    3
  • fYear
    1977
  • fDate
    3/1/1977 12:00:00 AM
  • Firstpage
    279
  • Lastpage
    281
  • Abstract
    The pulse emission and extended life test data on the tungstate cathode are reported. Life data on the operation of the tungstate cathode at dc densities from 33 mA/cm2to 30 A/cm2at operating temperatures from 600 to 1100 °C are given.
  • Keywords
    Cathodes; Electron tubes; Frequency; Implants; Life testing; Plasma displays; Plasma temperature; Space vector pulse width modulation; Tungsten; Voltage;