DocumentCode
1055885
Title
Pulse emission and extended life testing of the tungstate cathode
Author
Smith, Bernard ; Newman, Albert
Author_Institution
US Army Electronics Technology and Devices Laboratory (ECOM), Fort Monmouth, NJ
Volume
24
Issue
3
fYear
1977
fDate
3/1/1977 12:00:00 AM
Firstpage
279
Lastpage
281
Abstract
The pulse emission and extended life test data on the tungstate cathode are reported. Life data on the operation of the tungstate cathode at dc densities from 33 mA/cm2to 30 A/cm2at operating temperatures from 600 to 1100 °C are given.
Keywords
Cathodes; Electron tubes; Frequency; Implants; Life testing; Plasma displays; Plasma temperature; Space vector pulse width modulation; Tungsten; Voltage;
fLanguage
English
Journal_Title
Electron Devices, IEEE Transactions on
Publisher
ieee
ISSN
0018-9383
Type
jour
DOI
10.1109/T-ED.1977.18723
Filename
1478915
Link To Document