Title :
A calibration method for four-terminal-pair high-frequency resistance standards
Author :
Suzuki, Kiyoshi ; Aoki, Toshiaki ; Yokoi, Katsumi
Author_Institution :
Yokogawa-Hewlett-Packard Ltd., Tokyo, Japan
fDate :
4/1/1993 12:00:00 AM
Abstract :
A calibration method for four-terminal-pair (4TP) resistance standards (4TP-R-STDs) is developed for frequencies up to about 10 MHz. The calibration is performed using an error-correction equation for a 4TP system. This is derived from analysis of an eight-port error adapter. The derivation of the uncertainties is also discussed
Keywords :
calibration; electric resistance measurement; measurement errors; measurement standards; 10 MHz; 4TP-R-STDs; calibration; eight-port error adapter; error-correction equation; four-terminal-pair high-frequency resistance standards; uncertainties; Admittance; Bridge circuits; Calibration; Capacitance; Equations; Error correction; Frequency; Impedance; Measurement standards; Standards development;