DocumentCode :
1060116
Title :
Design of Damper to Protect the Field Coil of an HTS Synchronous Motor
Author :
Kim, H.M. ; Yoon, Y.S. ; Kwon, Y.K. ; Kim, Y.C. ; Lee, S.H. ; Hong, J.P. ; Song, J.B. ; Lee, H.G.
Author_Institution :
Korea Electrotechnol. Res. Inst., Changwon, South Korea
Volume :
19
Issue :
3
fYear :
2009
fDate :
6/1/2009 12:00:00 AM
Firstpage :
1683
Lastpage :
1686
Abstract :
High Temperature Superconducting (HTS) synchronous motors consist mainly of rotational (HTS coil) and stationery (copper coil) parts. The HTS coil running at a synchronous speed is not influenced by the magnetic field generated by the stator coil but is affected considerably at the initial or transient operation. Therefore, computational analysis to determine the optimal design of the damper is an important factor in protecting the field coil of a HTS synchronous motor. This paper presents the optimal design parameters of the damper for a 5 MW HTS synchronous motor using the computational analysis of the transient characteristics of the stator current, which is proportional to the alternating magnetic field of the stator coil.
Keywords :
damping; high-temperature superconductors; shock absorbers; superconducting coils; synchronous motor protection; HTS synchronous motor protection; computational analysis; damper; high temperature superconducting field coil; stator; transient characteristics; Damper; HTS field coil; HTS synchronous motor; design parameter; stator coil;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2009.2017842
Filename :
5067135
Link To Document :