  • Abstract
    Coaxial thermal voltage converters were compared among NIM, NIST, PTB, SIRI, and VSL in the frequency range from 10 MHz to 100 MHz. The comparisons were made from 1988 through 1990. The highly varied methods and underlying principles on which RF-DC difference determinations are based in each laboratory, the transport standards used, and the results of the comparisons are described. The results from the participating laboratories are in very good agreement; therefore, the authors believe that the determinations of RF-DC difference in this frequency range are very well established
  • Keywords
    convertors; measurement standards; voltage measurement; 10 to 100 MHz; 1988 to 1990; NIM; NIST; PTB; RF-DC difference; SIRI; VSL; thermal voltage converters; transport standards; Bolometers; Bridge circuits; Frequency conversion; Frequency response; Impedance measurement; Laboratories; Metrology; NIST; US Department of Commerce; Voltage;